Electroosmotic flow is caused by the Coulomb force induced by an electric field on net mobile electric charge in a solution. Because the chemical equilibrium between a solid surface and an electrolyte solution typically leads to the interface acquiring a net fixed electrical charge, a layer of mobile ions, known as an electrical double layer or Debye layer, forms in the region near the interface.
Calculated osmolarity = 2 Na + Glucose + Urea (all in mmol/L) As Na+ is the major extracellular cation, the sum of osmolarity of all other anions can be assumed to be equal to natremia, hence [Na+]x2 ≈ [Na+] + [anions] To calculate plasma osmolality use the following equation (typical in the US): = 2[Na +
The osmol gap is typically calculated with the following formula (all values in mmol/L): = = ([+] + [] + []) In non-SI laboratory units: Calculated osmolality = 2 x [Na mmol/L] + [glucose mg/dL] / 18 + [BUN mg/dL] / 2.8 + [ethanol/3.7] [3] (note: the values 18 and 2.8 convert mg/dL into mmol/L; the molecular weight of ethanol is 46, but empiric data shows that it does not act as an ideal ...
Electroosmotic pumps are fabricated from silica nanospheres [6] [7] or hydrophilic porous glass, the pumping mechanism is generated by an external electric field applied on an electric double layer (EDL), generates high pressures (e.g., more than 340 atm (34 MPa) at 12 kV applied potentials) and high flow rates (e.g., 40 ml/min at 100 V in a pumping structure less than 1 cm 3 in volume).
In physiology, transport maximum (alternatively Tm or T max) refers to the point at which increase in concentration of a substance does not result in an increase in movement of a substance across a cell membrane. In renal physiology, the concept of transport maximum is often discussed in the context of glucose and PAH. [citation needed]
Figure 2: Regulation of metabolic pathways maintains blood glucose concentration at approximately 5 mM in humans. Blood glucose levels are maintained at a steady state concentration by balancing the rate of entry of glucose into the blood stream (i.e. by ingestion or released from cells) and the rate of glucose uptake by body tissues. [1]
Blood glucose monitoring is the use of a glucose meter for testing the concentration of glucose in the blood . Particularly important in diabetes management , a blood glucose test is typically performed by piercing the skin (typically, via fingerstick ) to draw blood, then applying the blood to a chemically active disposable 'test-strip'.
When solute particles neither dissociate nor associate in solution, i equals 1 (e.g. glucose in water). The value of i is the actual number of particles in solution after dissociation divided by the number of formula units initially dissolved in solution and means the number of particles per formula unit of the solute when a solution is dilute.