Search results
Results from the WOW.Com Content Network
However, at higher distortion levels the discrepancy becomes large. For instance, a signal with THD F 266% has a THD R of 94%. [5] A pure square wave with infinite harmonics has THD F of 48.3% [1] [15] [16] and THD R of 43.5%. [17] [18] Some use the term "distortion factor" as a synonym for THD R, [19] while others use it as a synonym for THD F ...
In physics, the dissipation factor (DF) is a measure of loss-rate of energy of a mode of oscillation (mechanical, electrical, or electromechanical) in a dissipative system. It is the reciprocal of quality factor , which represents the "quality" or durability of oscillation.
The ratio of (a) total received power, i.e., the signal to (b) the noise-plus-distortion power. This is modeled by the equation above. [2] The ratio of (a) the power of a test signal, i.e. a sine wave, to (b) the residual received power, i.e. noise-plus-distortion power. With this definition, it is possible to have a SINAD level less than one.
The Q factor is a parameter that describes the resonance behavior of an underdamped harmonic oscillator (resonator). Sinusoidally driven resonators having higher Q factors resonate with greater amplitudes (at the resonant frequency) but have a smaller range of frequencies around that frequency for which they resonate; the range of frequencies for which the oscillator resonates is called the ...
The stretch factor of the pair is the ratio between these two distances, d(f(x),f(y))/d(x,y). The stretch factor of the whole mapping is the supremum of the stretch factors of all pairs of points. The stretch factor has also been called the distortion [disputed – discuss] or dilation of the mapping.
In continuum mechanics, the maximum distortion energy criterion (also von Mises yield criterion [1]) states that yielding of a ductile material begins when the second invariant of deviatoric stress reaches a critical value. [2] It is a part of plasticity theory that mostly applies to ductile materials, such as some metals.
Distortion occurs when the transfer function F is more complicated than this. If F is a linear function, for instance a filter whose gain and/or delay varies with frequency, the signal suffers linear distortion. Linear distortion does not introduce new frequency components to a signal but does alter the balance of existing ones.
A distortionmeter is a level meter with two switchable parallel circuits at the input. The first circuit measures the total signal at the output of a system. (For low distortion levels this will be almost equal to fundamental). That value is adjusted to read 100% or, equivalently, to 0 dB.