Search results
Results from the WOW.Com Content Network
[15] [16] For example, to maintain a 15 °C temperature in a certain dwelling about 3.0 kW of heating are required at 0 ACH (no heat loss due to warmed air leaving the dwelling, instead heat is lost due to conduction or radiation), 3.8 kW at 1 ACH and 4.5 kW are required at 2 ACH. [15]
ASHRAE Standard 62.2 was adopted in 2004; it clarifies the ventilation air requirements for low-rise residences. The Standard specifies that forced ventilation is required in houses with infiltration less than 0.35 ACH. [2] This is typically accomplished with heat recovery ventilation or exhaust fans running constantly or periodically.
The ventilation system of a regular earthship Dogtrot houses are designed to maximise natural ventilation. A roof turbine ventilator, colloquially known as a 'Whirly Bird' is an application of wind driven ventilation. Passive ventilation is the process of supplying air to and removing air from an indoor space without using mechanical systems.
The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect. The stack effect can be useful to drive natural ventilation in certain climates, but in other circumstances may be a cause of unwanted air infiltration or fire ...
The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.
The primary mode of heat transfer impeded by insulation is conduction, but insulation also reduces heat loss by all three heat transfer modes: conduction, convection, and radiation. The primary heat loss across an uninsulated air-filled space is natural convection, which occurs because of changes in air density with temperature. Insulation ...
A heat exchanger is the part of the system that transfers heat from the hot parts of the machine or a system to the cold parts of the machine or system. heat gain heat load heat loss Terms for the amount of cooling (heat gain) or heating (heat loss) needed to maintain desired temperatures and humidifies in controlled air.
The rate of heat flow is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second). Heat is the flow of thermal energy driven by thermal non-equilibrium, so the term 'heat flow' is a redundancy (i.e. a pleonasm). Heat must not be confused with stored thermal energy, and moving a hot ...