enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket." Liquidtight flexible nonmetallic conduit (LFNC) refers to several types of flame-resistant non-metallic tubing. Interior ...

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    This type of cable is the least expensive for a given size and is appropriate for dry indoor applications. The designation NM XX-Y indicates, respectively, the type of sheathing (in this case, non-metallic), the size of the main conductors, and the total number of circuit conductors (exclusive of the grounding conductor). For example, NM 14-2 ...

  4. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    The conduit methods were known to be of better quality, but cost significantly more than K&T. [2] In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. [6] Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.

  5. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    Electrical power cables are sometimes installed in raceways, including electrical conduit and cable trays, which may contain one or more conductors. When it is intended to be used inside a building, nonmetallic sheathed building cable (NM-B) consists of two or more wire conductors (plus a grounding conductor) enclosed inside a thermoplastic ...

  6. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    As of the 1999 National Electrical Code, AFCI protection is required in new construction on all 15- and 20-amp, 125-volt circuits to bedrooms. [ 11 ] Conduit and cable protection

  7. IEC 60364 - Wikipedia

    en.wikipedia.org/wiki/IEC_60364

    IEC 60364 Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings.This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364".

  8. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60724 Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) IEC TR 60725 Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase

  9. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    1/1 mm 2 and 1.5/1 mm 2 have solid conductors and CPC (primarily used on low power lighting or alarm circuits) 2.5/1.5mm 2 has a solid CPC and may have solid or stranded conductors (primarily used for socket circuits, radial or ring circuit) 4/1.5 mm 2 and 6/2.5 mm 2 have stranded conductors and a solid CPC (fixed high power equipment or sub-mains)