There are several alternatives for connecting newer appliances to two-prong receptacles without rewiring the building: removing the grounding pin of the plug (unsafe), replacing the receptacle with a three-prong outlet (unsafe without proper ground), or replacing the receptacle with a Ground Fault Circuit Interrupter (GFCI).
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...
BS 546, "Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50-60 Hz) circuits up to 250 V" describes four sizes of plug rated at 2 A, 5 A (Type D), 15 A (Type M) and 30 A. The plugs have three round pins arranged in a triangle, with the larger top pin being the earthing pin.
Plus the average GFCI receptacle costs about an hour's wages - or less. One GFCI receptacle can be used to protect a number of donwstream receptacles, if you're building a summer cottage or a doghouse or something and want to save $8 or so. And if you need to protect a permanently-wired apparatus, you can of course buy a GFCI circuit breaker.
240 V receptacle faces. The 1999 Code required that new 120/240 volt receptacles, such as those for electric ranges and dryers, be grounded also, which necessitates a fourth slot in their faces. Changes in standards often create problems for new work in old buildings. A 120 volt combination AFCI/GFCI receptacle
Failure to install a "feed-through" type GFCI to all electrical devices that are an integral part of a Swimming pool, or not testing it weekly. This is a particular concern due to the use of electric lights and pumps where persons are immersed in water. The GFCI has the typical "test" and "reset" buttons, but no plug-in outlets.
"Plugs, socket-outlets and couplers for industrial purposes" specifies general functional and safety requirements. [4] IEC 60309-2 "Dimensional interchangeability requirements for pin and contact-tube accessories" applies to plugs and socket-outlets, cable couplers and appliance couplers with pins and contact tubes of standardized configurations.
A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.