Ad
related to: venturi flow meter calculations for construction work and design
Search results
Results from the WOW.Com Content Network
Video of a Venturi meter used in a lab experiment Idealized flow in a Venturi tube. The Venturi effect is the reduction in fluid pressure that results when a moving fluid speeds up as it flows from one section of a pipe to a smaller section. The Venturi effect is named after its discoverer, the 18th-century Italian physicist Giovanni Battista ...
In hydrology, a Venturi flume is a device used for measuring the rate of flow of a liquid in situations with large flow rates, such as a river. [1] It is based on the Venturi effect, for which it is named. [2] It was first developed by V.M. Cone in Fort Collins, Colorado. [3] The Venturi flume consists of a flume with a constricted section in ...
If there is submerged flow, adjustments need to be made in order for the Parshall Flume to work properly. The discharge (Q) can be found using the following equations and table: Q net = Q free flow – Q correction; Q correction = M (0.000132 H a 2.123 e 9.284 St) where: S, H b /H a; M, multiplying factor
The flow speed of a fluid can be measured using a device such as a Venturi meter or an orifice plate, which can be placed into a pipeline to reduce the diameter of the flow. For a horizontal device, the continuity equation shows that for an incompressible fluid, the reduction in diameter will cause an increase in the fluid flow speed.
As an example calculation using the above equation, assume that the propellant combustion gases are: at an absolute pressure entering the nozzle p = 7.0 MPa and exit the rocket exhaust at an absolute pressure p e = 0.1 MPa; at an absolute temperature of T = 3500 K; with an isentropic expansion factor γ = 1.22 and a molar mass M = 22 kg/kmol.
Choked flow is a fluid dynamic condition associated with the Venturi effect. When a flowing fluid at a given pressure and temperature passes through a constriction (such as the throat of a convergent-divergent nozzle or a valve in a pipe ) into a lower pressure environment the fluid velocity increases.
The original purpose of the Venturi meter was to measure the amount of water used by the individual water mills in the Holyoke area. [10] A flow of air through a venturi meter, showing the columns connected in a U-shape (a manometer) and partially filled with water. The meter is "read" as a differential pressure head in cm or inches of water.
A Venturi meter constricts the flow in some fashion, and pressure sensors measure the differential pressure before and within the constriction. This method is widely used to measure flow rate in the transmission of gas through pipelines, and has been used since Roman Empire times. The coefficient of discharge of
Ad
related to: venturi flow meter calculations for construction work and design