A computed tomography scan (CT scan), formerly called computed axial tomography scan (CAT scan), is a medical imaging technique used to obtain detailed internal images of the body. [2] The personnel that perform CT scans are called radiographers or radiology technologists.
In conventional CT machines, an X-ray tube and detector are physically rotated behind a circular shroud (see the image above right). An alternative, short lived design, known as electron beam tomography (EBT), used electromagnetic deflection of an electron beam within a very large conical X-ray tube and a stationary array of detectors to achieve very high temporal resolution, for imaging of ...
A full-body scan is a scan of the patient's entire body as part of the diagnosis or treatment of illnesses. If computed tomography ( CAT ) scan technology is used, it is known as a full-body CT scan , though many medical imaging technologies can perform full-body scans.
high strength (0.15 to 1.5 teslas) [4] are used to excite protons that produce the record results (like CT scan). It can show particular tissues more clearly than CT.; [4] video link: Linear accelerator: used in radiotherapy for cancer: Functional magnetic resonance imaging (fMRI) video link: Positron emission tomography (PET Scan) video link
X-ray computed tomography (CT), or Computed Axial Tomography (CAT) scan, is a helical tomography technique (latest generation), which traditionally produces a 2D image of the structures in a thin section of the body. In CT, a beam of X-rays spins around an object being examined and is picked up by sensitive radiation detectors after having ...
Low-dose high-resolution (1.25 mm) chest CT. HRCT is performed using a conventional CT scanner. However, imaging parameters are chosen so as to maximize spatial resolution: [1] a narrow slice width is used (usually 1–2 mm), a high spatial resolution image reconstruction algorithm is used, field of view is minimized, so as to minimize the size of each pixel, and other scan factors (e.g. focal ...
Electron beam CT scanners are considered a fifth generation CT scanner, with first generation being the pencil beam with translation and rotation, second generation being a fan beam with similar motion to its predecessor, third generation having both rotating fan beam and detectors and fourth generation being a fan beam with a rotating movement but fixed detector.
As an example, each mm 2 of a CT detector may receive several hundred million photon interactions per second during a scan. [ 4 ] To avoid saturation in areas where little material is present between the X-ray source and the detector, the pulse resolving time must be small compared to the average time between photon interactions in a pixel.