Search results
Results from the WOW.Com Content Network
A structure of shear walls in the center of a large building—often encasing an elevator shaft or stairwell—form a shear core. In multi-storey commercial buildings, shear walls form at least one core (Figure 3). From a building services perspective, the shear core houses communal services including stairs, lifts, toilets and service risers.
The Ritz-Carlton/JW Marriott hotel building, a part of the LA Live development in Los Angeles, California, is the first building in Los Angeles that uses an advanced steel plate shear wall system to resist the lateral loads of strong earthquakes and winds.
In structural engineering, a diaphragm is a structural element that transmits lateral loads to the vertical resisting elements of a structure (such as shear walls or frames). Diaphragms are typically horizontal but can be sloped in a gable roof on a wood structure or concrete ramp in a parking garage.
Partial soft story collapse due to inadequate shear strength at ground level during the Loma Prieta earthquake.. A soft story building is a multi-story building in which one or more floors have windows, wide doors, large unobstructed commercial spaces, or other openings in places where a shear wall would normally be required for stability as a matter of earthquake engineering design.
A shear wall, in its simplest definition, is a wall where the entire material of the wall is employed in the resistance of both horizontal and vertical loads. A typical example is a brick or cinderblock wall. Since the wall material is used to hold the weight, as the wall expands in size, it must hold considerably more weight.
By 1963, a new structural system of framed tubes had appeared in skyscraper design and construction. Fazlur Rahman Khan, a structural engineer from Bangladesh (then called East Pakistan) who worked at Skidmore, Owings & Merrill, defined the framed tube structure as "a three dimensional space structure composed of three, four, or possibly more frames, braced frames, or shear walls, joined at or ...
Capacity design of structures is: to control failure in a building by pre-selecting localized ductile fuses (or weak links) to act as the primary location for energy dissipation when a building is subjected to extreme loading. The structure is designed such that all inelastic action (or damage) occurs at these critical locations (the fuses ...
Shear wall frame interaction system: The Cook County Administration Building in Chicago was the first to utilize a shear wall frame interaction system. Khan developed the shear wall frame interaction system for mid high-rise buildings. This structural system uses combinations of shear walls and frames designed to resist lateral forces. [77]