enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Skin effect - Wikipedia

    en.wikipedia.org/wiki/Skin_effect

    The most important effect of skin effect on the impedance of a single wire is the increase of the wire's resistance, and consequent losses. The effective resistance due to a current confined near the surface of a large conductor (much thicker than δ ) can be solved as if the current flowed uniformly through a layer of thickness δ based on the ...

  3. Litz wire - Wikipedia

    en.wikipedia.org/wiki/Litz_wire

    Examples of skin depth in copper wire at different frequencies At 60 Hz the skin depth of a copper wire is about 7.6 mm (0.30 inches). At 60,000 Hz (60 kHz) the skin depth of copper wire is about 0.25 mm (0.0098 inches). At 6,000,000 Hz (6 MHz) [5] the skin depth of copper wire is about 25 μm (0.00098 inches).

  4. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    The skin effect benefits the design, as it causes the current to be concentrated towards the low-resistivity aluminum on the outside of the conductor. To illustrate the impact of the skin effect, the American Society for Testing and Materials (ASTM) standard includes the conductivity of the steel core when calculating the DC and AC resistance ...

  5. Wheeler incremental inductance rule - Wikipedia

    en.wikipedia.org/wiki/Wheeler_Incremental...

    Stripline illustrating the incremental Wheeler inductance rule. The incremental inductance rule, attributed to Harold Alden Wheeler [1] by Gupta [2]: 101 and others [3]: 80 is a formula used to compute skin effect resistance and internal inductance in parallel transmission lines when the frequency is high enough that the skin effect is fully developed.

  6. Copper-clad aluminium wire - Wikipedia

    en.wikipedia.org/wiki/Copper-clad_aluminium_wire

    This improved conductivity over bare aluminum makes the copper-clad aluminium wire a good fit for radio frequency use. The skin effect is similarly exploited in copper-clad steel wire, such as the center conductors of many coaxial cables, which are commonly used for high frequency feedlines with high strength and conductivity requirements.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  8. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    The table below assumes DC, or AC frequencies equal to or less than 60 Hz, and does not take skin effect into account. "Turns of wire per unit length" is the reciprocal of the conductor diameter; it is therefore an upper limit for wire wound in the form of a helix (see solenoid), based on uninsulated wire.

  9. Switched-mode power supply - Wikipedia

    en.wikipedia.org/wiki/Switched-mode_power_supply

    For these frequencies, the skin effect is only significant when the conductors are large, more than 0.3 inches (7.6 mm) in diameter. Switching power supplies must pay more attention to the skin effect because it is a source of power loss. At 500 kHz, the skin depth in copper is about 0.003 inches (0.076 mm) – a dimension smaller than the ...