ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]
There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.
The following is a list of U.S. based energy codes and standards that reference building simulations to demonstrate compliance: ASHRAE 90.1; International Energy Conservation Code (IECC) Leadership in Energy and Environmental Design (LEED) Green Globes; California Title 24; EnergyStar Multifamily High rise Program; Passive House Institute US ...
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
The thermal insulation requirements in the USA follow the ASHRAE 90.1 which is the U.S. energy standard for all commercial and some residential buildings. [13] ASHRAE 90.1 standard considers multiple perspectives such as prescriptive, building envelope types and energy cost budget.
A module for Appendix G of ASHRAE 90.1-2010 is available, this is used for example in LEED and BREEAM. The integrated radiosity method with single reflection and one measuring point can be used for whole-year daylight analysis and allows modeling daylight-based control strategies (e.g. shading devices, artificial lightening).
These features will make this cluster 21.7% more energy efficient than the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1 - 2004 standards. [26] will also consume 30% less water than the standards set by U.S. Environmental Protection Agency (EPA) as well as 40% less irrigation water. These savings have ...