enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    Waffle slabs are preferred for spans greater than 40 feet (12 m), because, for a given mass of concrete, they are much stronger than flat slabs, flat slabs with drop panels, two-way slabs, one-way slabs, and one-way joist slabs. [2] Section of a waffle slab including beam, ribs, and column head

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. Box girder - Wikipedia

    en.wikipedia.org/wiki/Box_girder

    A box girder or tubular girder (or box beam) is a girder that forms an enclosed tube with multiple walls, as opposed to an Ɪ-or H-beam. Originally constructed of wrought iron joined by riveting , they are now made of rolled or welded steel, aluminium extrusions or prestressed concrete .

  5. Open web steel joist - Wikipedia

    en.wikipedia.org/wiki/Open_web_steel_joist

    The LH- and DLH-Series have been designed for the purpose of extending the use of joists to spans and loads in excess of those covered by Open Web Steel Joists, K-Series. LH-Series Joists have been standardized in depths from 18 inches (460 mm) through 48 inches (1,200 mm), for spans through 96 feet (29,000 mm).

  6. I-joist - Wikipedia

    en.wikipedia.org/wiki/I-joist

    The rim joist depth must match the I-joist size. Mismatches can strain the joist. A similar situation occurs where the I-joist crosses a main beam. Installing squash blocks (2×4 materials 1 ⁄ 16 in or 1.6 mm higher than the I-joist) alongside the I-joists transfers the load from the I-joist onto the beam. Missed nails and glue setting too ...

  7. Joist - Wikipedia

    en.wikipedia.org/wiki/Joist

    A double floor is a floor framed with joists supported by larger timbers.. In traditional timber framing there may be a single set of joists which carry both a floor and ceiling called a single floor (single joist floor, single framed floor) or two sets of joists, one carrying the floor and another carrying the ceiling called a double floor (double framed floor).

  8. Span (engineering) - Wikipedia

    en.wikipedia.org/wiki/Span_(engineering)

    In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...

  9. Insulating concrete form - Wikipedia

    en.wikipedia.org/wiki/Insulating_concrete_form

    The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...