  1. Results from the WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  4. Barometric formula - Wikipedia

    en.wikipedia.org/wiki/Barometric_formula

    In these equations, g 0, M and R * are each single-valued constants, while ρ, L, T and h are multi-valued constants in accordance with the table below. The values used for M , g 0 and R * are in accordance with the U.S. Standard Atmosphere , 1976, and that the value for R * in particular does not agree with standard values for this constant.

  5. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    Atmospheric pollutant concentrations expressed as mass per unit volume of atmospheric air (e.g., mg/m 3, μg/m 3, etc.) at sea level will decrease with increasing altitude because the atmospheric pressure decreases with increasing altitude. The change of atmospheric pressure with altitude can be obtained from this equation: [2]

  6. NTU method - Wikipedia

    en.wikipedia.org/wiki/NTU_Method

    The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...

  7. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Most often, the air outlets and inlets are placed in the ceiling. Supply diffusers in the ceiling are fed by fan coil units in the ceiling void or by air handling units in a remote plant room. The fan coil or handling unit takes in return air from the ceiling void and mix this with fresh air and cool, or heat it, as required to achieve the room ...

  8. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:

  9. IDA Indoor Climate and Energy - Wikipedia

    en.wikipedia.org/wiki/IDA_Indoor_Climate_and_Energy

    A simple procedure for calculating and reporting cooling, heating, air demand, and energy, together with a built-in version handling system, makes it efficient to compare different systems and results. Advanced daylight calculation are achieved by interfacing the Radiance lighting simulation tool with result visualization in the 3D environment.