enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Kelvin probe force microscope - Wikipedia

    en.wikipedia.org/wiki/Kelvin_probe_force_microscope

    The changes to the Fermi levels of the scanning Kelvin probe (SKP) sample and probe during measurement are shown. On the electrical connection of the probe and sample their Fermi levels equilibrate, and a charge develops at the probe and sample. A backing potential is applied to null this charge, returning the sample Fermi level to its original ...

  3. Fermi level - Wikipedia

    en.wikipedia.org/wiki/Fermi_level

    The Fermi level does not necessarily correspond to an actual energy level (in an insulator the Fermi level lies in the band gap), nor does it require the existence of a band structure. Nonetheless, the Fermi level is a precisely defined thermodynamic quantity, and differences in Fermi level can be measured simply with a voltmeter.

  4. Volta potential - Wikipedia

    en.wikipedia.org/wiki/Volta_potential

    The Volta potential of a metal surface can be mapped on very small scales by use of a Kelvin probe force microscope, based on atomic force microscopy. Over larger areas on the order of millimeters to centimeters, a scanning Kelvin probe (SKP), which uses a wire probe of tens to hundreds of microns in size, can be used. In either case the ...

  5. Work function - Wikipedia

    en.wikipedia.org/wiki/Work_function

    Kelvin probe energy diagram at flat vacuum configuration, used for measuring work function difference between sample and probe. The Kelvin probe technique relies on the detection of an electric field (gradient in ϕ) between a sample material and probe material. The electric field can be varied by the voltage ΔV sp that is applied to the probe ...

  6. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  7. Fermi energy - Wikipedia

    en.wikipedia.org/wiki/Fermi_energy

    The Fermi energy is only defined at absolute zero, while the Fermi level is defined for any temperature. The Fermi energy is an energy difference (usually corresponding to a kinetic energy), whereas the Fermi level is a total energy level including kinetic energy and potential energy.

  8. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    That means that the contact resistance of the probes and their leads is inseparable from the resistance of the contact area to be measured, with which they are in series. In a four-terminal measurement, the current used to make the measurement is injected using a second, separate pair of leads, so the contact resistance of the measurement ...

  9. Surface photovoltage - Wikipedia

    en.wikipedia.org/wiki/Surface_photovoltage

    Surface photovoltage measurements are performed by placing a wafer or sheet film of a semiconducting material on a ground electrode and positioning a kelvin probe a small distance above the sample. The surface is illuminated with light of fixed wavelength in industrial applications or with light whose wavelength is scanned using a monochromator ...