Search results
Results from the WOW.Com Content Network
X-ray showing the proximal portion of a fractured tibia with an intramedullary nail Proximal femur nail with locking and stabilisation screws for treatment of femur fractures of left thigh An intramedullary rod , also known as an intramedullary nail (IM nail) or inter-locking nail or Küntscher nail (without proximal or distal fixation), is a ...
For femoral shaft fractures, reduction and intramedullary nailing is currently recommended. [14] The bone is re-aligned, then a metal rod is placed into the femoral bone marrow, and secured with nails at either end. This method offers less exposure, a 98–99% union rate, lower infection rates (1–2%) and less muscular scarring. [14] [15] [17]
A hip fracture is a break that occurs in the upper part of the femur (thigh bone), at the femoral neck or (rarely) the femoral head. [2] Symptoms may include pain around the hip, particularly with movement, and shortening of the leg. [2] Usually the person cannot walk. [3] A hip fracture is usually a femoral neck fracture.
X-ray of Femoral Osteotomy hardware to correct femoral rotation caused by hip dysplasia. X-ray of the right hip in female patient in early thirties. Two main types of osteotomies are used in the correction of hip dysplasias and deformities to improve alignment/interaction of acetabulum – (socket) – and femoral head – (ball), innominate osteotomies and femoral osteotomies.
Bone malrotation refers to the situation that results when a bone heals out of rotational alignment from another bone, or part of bone. It often occurs as the result of a surgical complication after a fracture where intramedullary nailing (IMN) occurs, [1] especially in the femur and tibial bones, but can also occur genetically at birth.
Hip fracture (anatomically a fracture of the femur bone and not the hip bone) Patella fracture; Crus fracture. Tibia fracture. Pilon fracture; Tibial plateau fracture; Bumper fracture – a fracture of the lateral tibial plateau caused by a forced valgus applied to the knee; Segond fracture – an avulsion fracture of the lateral tibial condyle
His advocacy of the use of Thomas splint for the initial treatment of femoral fractures reduced mortality of open fractures of the femur from 87% to less than 8% in the period from 1916 to 1918. [9] The use of intramedullary rods to treat fractures of the femur and tibia was pioneered by Gerhard Küntscher of Germany.
Telescoping IM rods are widely used, [119] and the common Fassier–Duval IM rod is designed to be used to rod the femur, tibia, and humerus. [120]: 1 The surgery involves breaking the long bones in between one and three (or more) [119]: Figure 4 places, then fixing the rod alongside the bone to keep it straight. [120]: 11