A potentiometric sensor is a type of chemical sensor that may be used to determine the analytical concentration of some components of the analyte gas or solution. These sensors measure the electrical potential of an electrode when no current is present.
Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...
The design of the electrodes is the key part: These are rod-like structures usually made of glass, with a bulb containing the sensor at the bottom. The glass electrode for measuring the pH has a glass bulb specifically designed to be selective to hydrogen-ion concentration.
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential. ISE is a type ...
Potential as a function of time for anodic stripping voltammetry Three-electrode setup: (1) working electrode; (2) counter electrode; (3) reference electrode. Voltammetry experiments investigate the half-cell reactivity of an analyte. Voltammetry is the study of current as a function of applied potential. These curves I = f(E) are called ...
In other words, 2 moles of electrons are consumed per mole of water. 2 I − → I 2 + 2 e − B·I 2 + B·SO 2 + B + H 2 O → 2 BH + I − + BSO 3 BSO 3 + ROH → BHRSO 4. The end point is detected most commonly by a bipotentiometric titration method. A second pair of Pt electrodes is immersed in the anode solution.
A redox indicator (also called an oxidation-reduction indicator) is an indicator which undergoes a definite color change at a specific electrode potential. The requirement for fast and reversible color change means that the oxidation-reduction equilibrium for an indicator redox system needs to be established very quickly. Therefore, only a few ...
A potentiometer being calibrated and then measuring an unknown voltage. R 1 is the resistance of the entire resistance wire. The arrow head represents the moving wiper.. In this circuit, the ends of a uniform resistance wire R 1 are connected to a regulated DC supply V S for use as a voltage divider.