enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Polarity (mutual inductance) - Wikipedia

    en.wikipedia.org/wiki/Polarity_(mutual_inductance)

    These markings may be found on transformer cases beside terminals, winding leads, nameplates, schematic and wiring diagrams. The convention is that current entering a transformer at the end of a winding marked with a dot, will tend to produce current exiting other windings at their dotted ends.

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    On the three secondary terminals, the center tap is grounded with a short strap to the transformer case. A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage ...

  5. Wiring diagram - Wikipedia

    en.wikipedia.org/wiki/Wiring_diagram

    An automotive wiring diagram, showing useful information such as crimp connection locations and wire colors. These details may not be so easily found on a more schematic drawing. A wiring diagram is a simplified conventional pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes, and the ...

  6. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.

  7. Circuit diagram - Wikipedia

    en.wikipedia.org/wiki/Circuit_diagram

    A circuit diagram (or: wiring diagram, electrical diagram, elementary diagram, electronic schematic) is a graphical representation of an electrical circuit. A pictorial circuit diagram uses simple images of components, while a schematic diagram shows the components and interconnections of the circuit using standardized symbolic representations.

  8. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example delta-wye transformer schematic. A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three ...

  9. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.