enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Humphrey visual field analyser - Wikipedia

    en.wikipedia.org/wiki/Humphrey_Visual_Field_Analyser

    The numerical display represents raw values of patient's retinal sensitivity at specific retinal points in dB. Higher numbers equate to higher retinal sensitivities. Sensitivity is greatest in the central field and decreases towards the periphery. Normal values are approximately 30 dB while recorded values of <0 dB equate to no sensitivity ...

  3. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  4. Keratoconus - Wikipedia

    en.wikipedia.org/wiki/Keratoconus

    Keratoconus is the most common grounds for conducting a penetrating keratoplasty, generally accounting for around a quarter of such procedures. [60] The corneal transplant surgeon trephines a lenticule of corneal tissue and then grafts the donor cornea to the existing eye tissue, usually using a combination of running and individual sutures.

  5. Corneal topography - Wikipedia

    en.wikipedia.org/wiki/Corneal_topography

    Keratoconus in itself is a pattern of the entire cornea, therefore every measurement just focusing on one layer, might not be enough for a state of the art diagnosis. Especially early cases of keratoconus might be missed by a plain topographic measurement, which is critical if refractive surgery is being considered. [ 7 ]

  6. Corneal cross-linking - Wikipedia

    en.wikipedia.org/wiki/Corneal_cross-linking

    Corneal cross-linking (CXL) with riboflavin (vitamin B 2) and UV-A light is a surgical treatment for corneal ectasia such as keratoconus, PMD, and post-LASIK ectasia. It is used in an attempt to make the cornea stronger. According to a 2015 Cochrane review, there is insufficient evidence to determine if it is useful in keratoconus. [2]

  7. Visual field test - Wikipedia

    en.wikipedia.org/wiki/Visual_field_test

    Perimetry or campimetry is one way to systematically test the visual field. [1] [failed verification] It is the systematic measurement of differential light sensitivity in the visual field by the detection of the presence of test targets on a defined background. Perimetry more carefully maps and quantifies the visual field, especially at the ...

  8. Pellucid marginal degeneration - Wikipedia

    en.wikipedia.org/wiki/Pellucid_marginal_degeneration

    Examples of surgical procedures used for PMD include: wedge resection, lamellar crescentic resection, penetrating keratoplasty, lamellar keratoplasty, epikeratoplasty and intracorneal segments. Transplantation of the entire thickness of the cornea (penetrating keratoplasty) may be performed if there is enough normal tissue present.

  9. Neurotrophic keratitis - Wikipedia

    en.wikipedia.org/wiki/Neurotrophic_keratitis

    Corneal sensitivity test: performed by placing a cotton wad or cotton thread in contact with the corneal surface: this only allows to determine whether corneal sensitivity is normal, reduced or absent; or using an esthesiometer that allows to assess corneal sensitivity. Tear film function test, such as Schirmer's test, and tear film break-up time.