enow.com Web Search

  1. Ad

    related to: chilled water pipe size calculation

Search results

  1. Results from the WOW.Com Content Network
  2. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    Minimum efficiency requirements for many types of HVAC equipment were revised. Other revisions affect the maximum fan power limits, pump head calculation, chilled water pipe sizing, radiant panel insulation, single-zone VAV, and supply air temperature reset. Energy recovery is required for many more HVAC systems.

  3. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    A chiller used to create chilled water as part of a chilled water system. Chilled water is a commodity often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. The chilled water can be supplied by a vendor, such as a public utility, or created at the ...

  4. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  5. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  6. Run-around coil - Wikipedia

    en.wikipedia.org/wiki/Run-around_coil

    A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy.

  7. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc. With the two-pipe reverse ...

  8. Copper tubing - Wikipedia

    en.wikipedia.org/wiki/Copper_tubing

    While pipe sizes in Australia are inch-based, they are classified by outside rather than inside diameter (e.g., a nominal 3 ⁄ 4 inch copper pipe in Australia has measured diameters of 0.750 inches outside and 0.638 inches inside, whereas a nominal 3 ⁄ 4 inch copper pipe in the U.S. and Canada has measured diameters of 0.875 inch outside and ...

  9. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The equipment used can consist of machines used to remove heat such as a chiller or a cooling tower and equipment for adding heat to the building's water such as a boiler or a commercial water heater. Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units ...

  1. Ad

    related to: chilled water pipe size calculation