enow.com Web Search

  1. Ads

    related to: chilled water pump sizing calculator free

Search results

  1. Results from the WOW.Com Content Network
  2. Freeze stat - Wikipedia

    en.wikipedia.org/wiki/Freeze_stat

    Air coil freeze stat. A freeze stat is a temperature sensing device for HVAC that monitors a heat exchanger to prevent its coils from freezing.Freeze stats can be used on both refrigerant-to-air, and refrigerant-to-liquid type heat exchangers and serve different purposes with similar goals for each.

  3. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    The water in the chilled water circuit will be lowered to the Wet-bulb temperature or dry-bulb temperature before proceeding to the water chiller, where it is cooled to between 3 and 6 °C and pumped to the air handler, where the cycle is repeated. [3] The equipment required includes chillers, cooling towers, pumps and electrical control ...

  4. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]

  5. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  6. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    This avoids one of the principal challenges faced by the larger, two-part pumps: maintaining a water-tight seal at the point where the pump drive shaft enters the pump body. Small- to medium-sized circulator pumps are usually supported entirely by the pipe flanges that join them to the rest of the hydronic plumbing. Large pumps are usually pad ...

  7. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  1. Ads

    related to: chilled water pump sizing calculator free