Unit malfunction Battery failure, component malfunction, or generator failure [4] Problems at the insertion site Infection of the insertion site can cause local inflammation or the formation of an abscess in the pulse generator pocket. [2] Infection can cause the erosion of part of the pacing system that is in the skin. [2]
A right bundle branch block typically causes prolongation of the last part of the QRS complex and may shift the heart's electrical axis slightly to the right. The ECG will show a terminal R wave in lead V1 and a slurred S wave in lead I. Left bundle branch block widens the entire QRS, and in most cases shifts the heart's electrical axis to the ...
The bundle of His (BH) [1]: 58 or His bundle (HB) [1]: 232 (/ h ɪ s / "hiss" [2]) is a collection of heart muscle cells specialized for electrical conduction.As part of the electrical conduction system of the heart, it transmits the electrical impulses from the atrioventricular node (located between the atria and the ventricles) to the point of the apex of the fascicular branches via the ...
Image showing the cardiac pacemaker or SA node, the primary pacemaker within the electrical conduction system of the heart The cardiac pacemaker is the heart 's natural rhythm generator. It employs pacemaker cells that produce electrical impulses, known as cardiac action potentials , which control the rate of contraction of the cardiac muscle ...
An implantable cardioverter-defibrillator (ICD) is a battery-powered device that monitors electrical activity in the heart, and when an arrhythmia is detected, can deliver an electrical shock to terminate the abnormal rhythm. ICDs are used to prevent sudden cardiac death (SCD) in those who have survived a prior episode of sudden cardiac arrest ...
Graphical representation of the electrical conduction system of the heart that maintains the heart rate in the cardiac cycle. Electrical signals arising in the SA node (located in the right atrium) stimulate the atria to contract. Then the signals travel to the atrioventricular node (AV node), which is located in the interatrial septum.
This results in the heart being less able to pump blood effectively and also may cause electrical conduction problems. [3] Specifically, within the bundle branches that conduct impulses through the interventricular septum and into the Purkinje fibers , as these are responsible for the depolarization of contractile cells of both ventricles.
The primary purpose of a pacemaker is to maintain an even heart rate, either because the heart's natural cardiac pacemaker provides an inadequate or irregular heartbeat, or because there is a block in the heart's electrical conduction system. Modern pacemakers are externally programmable and allow a cardiologist to select the optimal pacing ...