  1. Results from the WOW.Com Content Network
  2. Calipers - Wikipedia

    en.wikipedia.org/wiki/Calipers

    A vernier caliper clamping on an object. Caliper(s) or calliper(s) are an instrument used to measure the linear dimensions of an object or hole; namely, the length, width, thickness, diameter or depth of an object or hole. The word "caliper" comes from a corrupt form of caliber. [1] [2] [3]

  3. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The test equipment being calibrated can be just as accurate as the working standard. [10] If the accuracy ratio is less than 4:1, then the calibration tolerance can be reduced to compensate. When 1:1 is reached, only an exact match between the standard and the device being calibrated is a completely correct calibration.

  4. Micrometer (device) - Wikipedia

    en.wikipedia.org/wiki/Micrometer_(device)

    A micrometer, sometimes known as a micrometer screw gauge (MSG), is a device incorporating a calibrated screw widely used for accurate measurement of components [1] in mechanical engineering and machining as well as most mechanical trades, along with other metrological instruments such as dial, vernier, and digital calipers.

  5. Vernier scale - Wikipedia

    en.wikipedia.org/wiki/Vernier_scale

    The standard for a caliper is usually a constant of 0.02 Vernier caliper scale with the normal 0.02 vernier constant, showing measurement of object at 19.44 mm to two decimal places. The use of the vernier scale is shown on a vernier caliper which measures the internal and the external diameters of an object.

  6. Quality control system for paper, board and tissue machines

    en.wikipedia.org/wiki/Quality_control_system_for...

    For a 1 meter wide web, for instance, 100 - 200 measurement values are taken. These measurement values from a single scan (profile points) are called 'raw profiles'. In modern quality control systems, the width of these data boxes can be changed, and accurate profiles can be formed using several thousands profile data boxes.

  7. Bore gauge - Wikipedia

    en.wikipedia.org/wiki/Bore_gauge

    When using a micrometer to set a dial bore gauge, the accuracy of the measurement will be 0.002 inches or 0.0508 millimeters. A ring gauge can be used to obtain higher accuracy at a higher cost and higher time requirement. When a dial bore gauge is set using a ring gauge, overall accuracy can be within 0.0001 inches or 0.00254 millimeter. [2]

  8. ANOVA gauge R&R - Wikipedia

    en.wikipedia.org/wiki/ANOVA_gauge_R&R

    Test methods, how the devices are set up, the test fixtures, how the data is recorded, etc. Specification , the measurement is reported against a specification or a reference value. The range or the engineering tolerance does not affect the measurement, but is an important factor in evaluating the viability of the measurement system.

  9. Facility condition assessment - Wikipedia

    en.wikipedia.org/wiki/Facility_condition_assessment

    Facility condition assessment is an analysis of the condition of a facility in terms of age, design, construction methods, and materials. [1] [2] The individuals who perform the assessment are typically architects and engineers, and skilled-trade technicians. Engineering and architectural professional opinions as to the conditions observed are ...