enow.com Web Search

  1. Ad

    related to: vapor barrier in residential building code

Search results

  1. Results from the WOW.Com Content Network
  2. Vapor barrier - Wikipedia

    en.wikipedia.org/wiki/Vapor_barrier

    American building codes started classifying vapor retarders in the 2007 IRC supplement. They are Class I <0.1 perm, Class II 0.1 - 1 perm and Class III 1-10 perm when tested in accordance with the ASTM E96 desiccant, dry cup or method A. [ 1 ] Vapor-retarding materials are generally categorized as:

  3. Housewrap - Wikipedia

    en.wikipedia.org/wiki/Housewrap

    Housewrap functions as a weather-resistant barrier, preventing rain or other forms of moisture from getting into the wall assembly while allowing water vapor to pass to the exterior. If moisture from either direction is allowed to build up within stud or cavity walls, mold and rot can set in and fiberglass or cellulose insulation will lose its ...

  4. Superinsulation - Wikipedia

    en.wikipedia.org/wiki/Superinsulation

    The 2009 International Residential Code embodies more sophisticated rules to guide the choice of insulation on the exterior of new homes, which can be applied when retrofitting older homes. A vapor-permeable building wrap on the outside of the original wall helps keep the wind out and allows the wall assembly to dry to the exterior.

  5. Building envelope - Wikipedia

    en.wikipedia.org/wiki/Building_envelope

    In order to achieve these objectives, all building enclosure systems must include a solid structure, a drainage plane, an air barrier, a thermal barrier, and may include a vapor barrier. Moisture control (e.g. damp proofing) is essential in all climates, but cold climates and hot-humid climates are especially demanding. [8]

  6. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    Open-cell foam is porous, allowing water vapor and liquid water to penetrate the insulation. Closed-cell foam is non-porous, and not moisture-penetrable, thereby effectively forming a semi-permeable vapor barrier. (N.B., vapor barriers are usually required by the Building Codes, regardless of the type of insulation used.

  7. Damp proofing - Wikipedia

    en.wikipedia.org/wiki/Damp_proofing

    Damp proofing in construction is a type of moisture control applied to building walls and floors to prevent moisture from passing into the interior spaces. Dampness problems are among the most frequent problems encountered in residences. DPC visible between concrete foundation and brickwork.

  8. Cellulose insulation - Wikipedia

    en.wikipedia.org/wiki/Cellulose_insulation

    Building codes in most American cities require a vapor barrier or retarder on the inside of an exterior wall in order to prevent moisture from the warm interior from condensing inside the wall and causing mold or rot. However, many building officials will waive the requirement when a good reason is provided.

  9. Moisture vapor transmission rate - Wikipedia

    en.wikipedia.org/wiki/Moisture_vapor...

    The building materials industry also manages the moisture barrier properties in architectural components to ensure the correct moisture levels in the internal spaces of buildings. Optoelectronic devices based on organic material, generally named OLEDs , need an encapsulation with low values of WVTR to guarantee the same performances over the ...

  1. Ad