An ACSR conductor can in part be denoted by its stranding, for example, an ACSR conductor with 72 aluminium strands with a core of 7 steel strands will be called 72/7 ACSR conductor. [ 3 ] [ 4 ] [ 5 ] Cables generally range from #6 AWG ("6/1" – six outer aluminum conductors and one steel reinforcing conductor) to 2167 kcmil ("72/7 ...
The ampacity, or maximum allowable current, of an electric power cable depends on the allowable temperatures of the cable and any adjacent materials such as insulation or termination equipment. For insulated cables, the insulation maximum temperature is normally the limiting material property that constrains ampacity.
Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps.
A single insulated conductor in free air has 70 A rating. Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor.
The skin effect and proximity effect cause conductors to exhibit higher resistance to alternating current (AC) than to direct current (DC). Due to the dual inverse nature of the electromagnetic field, the skin effect dominates at frequencies less than about 2 MHz; at higher frequencies, the proximity effect becomes the dominant force, and Litz wire induces more DC losses than solid wire or ...
A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.
Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...
Several kinds of ratings may be made available, including: real-time, indicating ampacity immediately available, without time limits should conditions remain identical; emergency ratings for a limited duration; and same-day and day-ahead forecasts. DLR computations deal with "near real-time" data, updated about every five minutes.