The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil. A test voltage is applied to the electrodes and is continuously increased up to the breakdown voltage with a constant, standard-compliant slew rate of e.g. 2 kV/s.
Oil sampling is a procedure for collecting a volume of fluid from lubricated or hydraulic machinery for the purpose of oil analysis. Much like collecting forensic evidence at a crime scene, when collecting an oil sample, it is important to ensure that procedures are used to minimize disturbance of the sample during and after the sampling process.
The cold-cranking simulator (CCS) is a device used to determine the low temperature performance of lubricants, when starting a cold engine (i.e. cold-cranking).In this condition, the only energy available to turn the engine comes from the starter motor and the battery, and it has been widely assumed that the system acts as a constant power viscometer.
The lubricity of a substance is not a material property, and cannot be measured directly. Tests are performed to quantify a lubricant's performance for a specific system. This is often done by determining how much wear is caused to a surface by a given wear-inducing object in a given amount of time. Other factors such as surface size ...
The dropping point test procedures are given in ASTM standards D-566 [2] and D-2265. [3] The test apparatus consists of a grease cup with a small hole in the bottom, test tube, two thermometers, a container, stirring device if required and an electric heater. The inside surfaces of the grease cup are coated with the grease to be tested.
A test method is a method for a test in science or engineering, such as a physical test, chemical test, or statistical test. It is a definitive procedure that produces a test result. [ 1 ] In order to ensure accurate and relevant test results, a test method should be "explicit, unambiguous, and experimentally feasible.", [ 2 ] as well as ...
In this test, a sample is heated at 250 °C for 60 minutes with a constant flow of air over it. The weight fraction lost is the result for the Noack volatility test. As the lighter hydrocarbon fraction of motor oils evaporate, the viscosity of the remaining oil increases, contributing to poor circulation, reduced fuel economy , increased oil ...
Ultraviolet (UV-A) radiation of adequate intensity (1,000 micro-watts per centimetre squared is common), along with low ambient light levels (less than 2 foot-candles) for fluorescent penetrant examinations. Inspection of the test surface should take place after 10- to 30-minute development time, and is dependent on the penetrant and developer ...