enow.com Web Search

  1. Ads

    related to: line pressure solenoid a control

Search results

  1. Results from the WOW.Com Content Network
  2. Variable force solenoid - Wikipedia

    en.wikipedia.org/wiki/Variable_force_solenoid

    A variable force solenoid (VFS) is an electro-hydraulic device that controls pressure proportionally or inversely proportionally to a signal (voltage or current) obtained from the on-board controller of a powertrain. A low flow VFS is used as a signal level devices for transmission line pressure control or application of clutches.

  3. Transmission control unit - Wikipedia

    en.wikipedia.org/wiki/Transmission_Control_Unit

    Newer automatic transmission designs often use many pressure control solenoids, and sometimes allow the shift solenoids themselves to provide precise pressure control during shifts by ramping the solenoid on and off. The shift pressure affects the shift quality (too high a pressure will result in rough shifting; too low a pressure will cause ...

  4. Solenoid (engineering) - Wikipedia

    en.wikipedia.org/wiki/Solenoid_(engineering)

    The solenoid can be useful for positioning, stopping mid-stroke, or for low velocity actuation; especially in a closed loop control system. A uni-directional solenoid would actuate against an opposing force or a dual solenoid system would be self cycling. The proportional concept is more fully described in SAE publication 860759 (1986).

  5. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    Solenoid valves. A solenoid valve is an electromechanically operated valve.. Solenoid valves differ in the characteristics of the electric current they use, the strength of the magnetic field they generate, the mechanism they use to regulate the fluid, and the type and characteristics of fluid they control.

  6. Electronically controlled unit injector - Wikipedia

    en.wikipedia.org/wiki/Electronically_controlled...

    The controlled part of the injector is a solenoid-operated spill valve. Normally, it is open, allowing the fuel to return to the supply line when the pump plunger descends. When the solenoid is energized, the spill valve closes, and the fuel is forced through the spray tip into the cylinder. The four phases of EUI operation are: Fill phase

  7. Transbrake - Wikipedia

    en.wikipedia.org/wiki/Transbrake

    Historically this was done with a modified valvebody and a single solenoid along with some internal transmission modifications, like increasing line pressure, and removing engine braking band and beefing up internal components to withstand the harsh launches, the valvebody and solenoid when activated allows hydraulic fluid to engage both ...

  1. Ads

    related to: line pressure solenoid a control