enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Thermal cutoff - Wikipedia

    en.wikipedia.org/wiki/Thermal_cutoff

    Another type of thermal switch is a PTC (Positive Temperature Coefficient) thermistor; these thermistors have a "cutting off" temperature at which the resistance suddenly rises rapidly, limiting the current through the circuit. When used in conjunction with a thermistor relay, the PTC will switch off an electrical system at a desired temperature.

  3. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped).

  4. Crowbar (circuit) - Wikipedia

    en.wikipedia.org/wiki/Crowbar_(circuit)

    A crowbar circuit is an electrical circuit used for preventing an overvoltage or surge condition of a power supply unit from damaging the circuits attached to the power supply. It operates by putting a short circuit or low resistance path across the voltage output (V o ), like dropping a crowbar across the output terminals of the power supply.

  5. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    An arc-fault circuit interrupter (AFCI) or arc-fault detection device (AFDD) [1] is a circuit breaker that breaks the circuit when it detects the electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.

  6. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    The circuit breaker closest to the downstream fault will send a restraining signal to prevent upstream breakers from tripping instantaneously. The presence of the fault will nevertheless activate the preset trip delay timer(s) of the upstream circuit breaker(s); this will allow an upstream circuit breaker to interrupt the fault, if still ...

  7. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    The prospective short-circuit current that can occur under short circuit conditions should not exceed the rated breaking capacity of the apparatus, otherwise breaking of the current cannot be guaranteed. The current breaking capacity corresponds to a certain voltage, so an electrical apparatus may have more than one breaking capacity current ...

  8. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    Analysis of the prospective short-circuit current is required for selection of protective devices such as fuses and circuit breakers. If a circuit is to be properly protected, the fault current must be high enough to operate the protective device within as short a time as possible; also the protective device must be able to withstand the fault ...

  9. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .