enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    A fixation disparity is not constant within a certain observer, but can vary depending on the viewing conditions. If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3).

  3. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    Prism fusion range. The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision (BSV) in the presence of increasing vergence demands.

  4. Maddox rod - Wikipedia

    en.wikipedia.org/wiki/Maddox_rod

    The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...

  5. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Maddox wing. The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the ...

  6. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Description (notes) AC. Anterior chamber. fluid-filled space between the iris and the endothelium. AC 4/4. Grade 4 anterior chamber angle. open angle between cornea and iris. AC 3/4. Grade 3 anterior chamber angle.

  7. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    Worth 4 dot test. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a single image.

  8. Vergence - Wikipedia

    en.wikipedia.org/wiki/Vergence

    The two eyes converge to point to the same object. A vergence is the simultaneous movement of both eyes in opposite directions to obtain or maintain single binocular vision. [1] When a creature with binocular vision looks at an object, the eyes must rotate around a vertical axis so that the projection of the image is in the centre of the retina ...

  9. Cover test - Wikipedia

    en.wikipedia.org/wiki/Cover_test

    A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations. The two primary types of cover tests are: the alternating cover test. the unilateral cover test (or the cover-uncover test).