Search results
Results from the WOW.Com Content Network
In the science of measurement, the least count of a measuring instrument is the smallest value in the measured quantity that can be resolved on the instrument's scale. [1] The least count is related to the precision of an instrument; an instrument that can measure smaller changes in a value relative to another instrument, has a smaller "least ...
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
A vernier caliper does not easily lose its calibration, but a sharp impact or accidental damage to the measuring surface in the caliper jaw can be significant enough to displace zero. [29] Digital calipers have zero set buttons, for quick recalibration. Vernier, dial and digital calipers can be used with accessories that extend their usefulness.
Using a vernier caliper to take measurements on a nut. The 1st two digits are decided by the location of the 0 on the lower scale. The last digit is determined by the 1st line on the lower scale that exactly matches the upper scale.
Vernier acuity is measured by asking participants to judge the offset between two parallel line segments with both eyes (binocular vision) or with each eye individually (monocular vision). [10] Vernier measures in infants and non-verbal children can be done using the preferential-looking technique [11] or by electrophysiological techniques. [12 ...
In computational geometry, the method of rotating calipers is an algorithm design technique that can be used to solve optimization problems including finding the width or diameter of a set of points. The method is so named because the idea is analogous to rotating a spring-loaded vernier caliper around the outside of a convex polygon . [ 1 ]
Vernier micrometer reading 5.783 ± 0.001 mm, comprising 5.5 mm on main screw lead scale, 0.28 mm on screw rotation scale, and 0.003 mm added from vernier. Some micrometers are provided with a vernier scale on the sleeve in addition to the regular graduations. These permit measurements within 0.001 millimetre to be made on metric micrometers ...
A traveling microscope. E—eyepiece, O—objective, K—knob for focusing, V—vernier, R—rails, S—screw for fine position adjustment. A travelling microscope is an instrument for measuring length with a resolution typically in the order of 0.01mm.