enow.com Web Search

  1. Ads

    related to: flexible rubber tubes for concrete walls and ceiling pipe sizes

Search results

  1. Results from the WOW.Com Content Network
  2. Tube (fluid conveyance) - Wikipedia

    en.wikipedia.org/wiki/Tube_(fluid_conveyance)

    A tube and pipe may be specified by standard pipe size designations, e.g., nominal pipe size, or by nominal outside or inside diameter and/or wall thickness. The actual dimensions of pipe are usually not the nominal dimensions: A 1-inch pipe will not actually measure 1 inch in either outside or inside diameter, whereas many types of tubing are ...

  3. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Flexible metallic tubing (FMT; North America) is not the same as flexible metallic conduit (FMC) which is described in US National Electrical Code (NEC) Article 348. FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes.

  4. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Fittings allow multiple pipes to be connected to cover longer distances, increase or decrease the size of the pipe or tube, or extend a network by branching, and make possible more complex systems than could be achieved with only individual pipes. Valves are specialized fittings that permit regulating the flow of fluid within a plumbing system.

  5. Pipe (fluid conveyance) - Wikipedia

    en.wikipedia.org/wiki/Pipe_(fluid_conveyance)

    Pipe sizes are documented by a number of standards, including API 5L, ANSI/ASME B36.10M (Table 1) in the US, and BS 1600 and BS 1387 in the United Kingdom. Typically the pipe wall thickness is the controlled variable, and the Inside Diameter (I.D.) is allowed to vary. The pipe wall thickness has a variance of approximately 12.5 percent.

  6. Sleeve (construction) - Wikipedia

    en.wikipedia.org/wiki/Sleeve_(construction)

    For example, a 4" pipe, with 1" of thermal insulation makes a 6" penetrant (1" pipe covering on each side of the pipe), plus two pipe sizes = an 8" sleeve, creating a 1" annulus. In case of insulated piping, the size of the insulation must be taken into account for the intended firestop certification listing .

  7. Capillary tube mat - Wikipedia

    en.wikipedia.org/wiki/Capillary_tube_mat

    The typical capillary tube mat has capillary tubes with an external diameter of less than 5 mm. This makes the construction very flexible, and emphasizes the property of the "mat". The individual capillary tubes are arranged in a grid with a spacing of 10 to max. 50 mm from each other.

  1. Ads

    related to: flexible rubber tubes for concrete walls and ceiling pipe sizes