In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]
[1] [2] [3] A key question is the uniformity of the flow distribution and pressure drop. Fig. 1. Manifold arrangement for flow distribution. Traditionally, most of theoretical models are based on Bernoulli equation after taking the frictional losses into account using a control volume (Fig. 2). The frictional loss is described using the Darcy ...
where is the Darcy friction factor (from the above equation or the Moody Chart), is the sublayer thickness, is the pipe diameter, is the density, is the friction velocity (not an actual velocity of the fluid), is the average velocity of the plug (in the pipe), is the shear on the wall, and is the pressure loss down the length of the pipe.
The key quantities are then the pressure drop along the pipe per unit length, Δp / L , and the volumetric flow rate. The flow rate can be converted to a mean flow velocity V by dividing by the wetted area of the flow (which equals the cross-sectional area of the pipe if the pipe is full of fluid).
The equation was derived by Kozeny (1927) [1] and Carman (1937, 1956) [2] [3] [4] from a starting point of (a) modelling fluid flow in a packed bed as laminar fluid flow in a collection of curving passages/tubes crossing the packed bed and (b) Poiseuille's law describing laminar fluid flow in straight, circular section pipes.
First, select the desired pressure loss Δp / L, say 1 kg / m 2 / s 2 (0.12 in H 2 O per 100 ft) on the vertical axis (ordinate). Next scan horizontally to the needed flow volume Q, say 1 m 3 / s (2000 cfm): the choice of duct with diameter D = 0.5 m (20 in.) will result in a pressure loss rate Δp / L less than the
The following table lists historical approximations to the Colebrook–White relation [23] for pressure-driven flow. Churchill equation [ 24 ] (1977) is the only equation that can be evaluated for very slow flow (Reynolds number < 1), but the Cheng (2008), [ 25 ] and Bellos et al. (2018) [ 8 ] equations also return an approximately correct ...