Search results
Results from the WOW.Com Content Network
A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark). [1] This is done to ensure that on normal conditions there is always current flowing and in the event of a line being cut the flow stops indefinitely, immediately raising the alarm of the event usually as the heavy noise of the teleprinter not being synchronized ...
A major application of current loops is the industry de facto standard 4–20 mA current loop for process control applications, where they are extensively used to carry signals from process instrumentation to proportional–integral–derivative (PID) controllers, supervisory control and data acquisition (SCADA) systems, and programmable logic ...
Following the patent and release of Harold's Long Scale calculator featuring two knobs on the outside rim in 1914, he designed the Magnum Long Scale calculator in 1927. [ 6 ] [ 7 ] As the name "Magnum" implies, it was a fairly large device at 4.5 inches in diameter—about 1.5 inches more than Fowler's average non-Magnum-series calculators. [ 8 ]
[4] Lower construction costs. [4] Temperature compensation is simple. [2] For larger currents conventional current transformers require an increase of the number of secondary turns, in order to keep the output current constant. Therefore, a Rogowski coil for large current is smaller than an equivalent rating current transformer. [5]
Nonetheless, it is often the case that such a circuit will provide adequate performance when the specified current and load resistance are small. For example, a 5 V voltage source in series with a 4.7 kΩ resistor will provide an approximately constant current of 1 mA ± 5% to a load resistance in the range of 50 to 450 Ω.
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
The Fuller calculator, sometimes called Fuller's cylindrical slide rule, is a cylindrical slide rule with a helical main scale taking 50 turns around the cylinder. This creates an instrument of considerable precision – it is equivalent to a traditional slide rule 25.40 metres (1,000 inches) long.
A non-isolated Ćuk converter comprises two inductors, two capacitors, a switch (usually a transistor), and a diode.Its schematic can be seen in figure 1. It is an inverting converter, so the output voltage is negative with respect to the input voltage.