  2. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    Early generator interlock kits consisted of two sliding steel or plastic (depending on the brand) plates held together by three bolts and installed on the front cover of the home's breaker panel, however, some models made by Eaton (formerly Cutler-Hammer) and Siemens for panels manufactured by them install on the adjacent circuit breakers themselves and consist of a sliding arm for breakers ...

  3. Interlock (engineering) - Wikipedia

    en.wikipedia.org/wiki/Interlock_(engineering)

    An interlock device is designed to allow a generator to provide backup power in such a way that it (a) prevents main and generator power to be connected at the same time, and (b) allows circuit breakers to operate normally without interference in the event of an overload condition. Most interlock devices for electrical systems employ a ...

  4. Trapped-key interlocking - Wikipedia

    en.wikipedia.org/wiki/Trapped-key_interlocking

    The key can then be used to unlock the kiln door. While the key is removed from the switch interlock, a plunger from the interlock mechanically prevents the power switch from being turned on. Power cannot be re-applied to the kiln until the kiln door is locked, releasing the key, and the key is then returned to the power switch interlock. [5]

  5. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Generator circuit breaker rated for 17.5 kV and 63 kA. Generator circuit breakers (GCB) are connected between a generator and the step-up voltage transformer. They are generally used at the outlet of high-power generators (30 MVA to 1800 MVA) in order to protect them in a reliable, fast and economic manner.

  6. Contact breaker - Wikipedia

    en.wikipedia.org/wiki/Contact_breaker

    Breaker arm with contact points at the left. The pivot is on the right and the cam follower is in the middle of the breaker arm. A contact breaker (or "points") is a type of electrical switch, found in the ignition systems of spark-ignition internal combustion engines. The switch is automatically operated by a cam driven by the engine.

  7. Interlocking - Wikipedia

    en.wikipedia.org/wiki/Interlocking

    Railway interlocking is of British origin, where numerous patents were granted. In June 1856, John Saxby received the first patent for interlocking switches and signals. [2] [3]: 23–24 In 1868, Saxby (of Saxby & Farmer) [4] was awarded a patent for what is known today in North America as “preliminary latch locking”.

  8. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    Generator switching applications are well known for their higher strains on interrupting devices, such as high fault current of high asymmetry or high and steep transient recovery voltage; the standard IEC/IEEE 62271-37-013 (former and still valid IEEE C37.013, 1997) was introduced to address such requirements on circuit breakers used in ...

  9. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.