Three terms are used to describe the configuration of a relay: pole, throw, and form. [5] Pole refers to the number of common terminals within a given switch. Throw refers to the number of positions in which the switch may be placed to create a signal path or connection. Figure lA illustrates a single-pole, single-throw normally open switch ...
Electromechanical protective relays operate by either magnetic attraction, or magnetic induction. [9]: 14 Unlike switching type electromechanical relays with fixed and usually ill-defined operating voltage thresholds and operating times, protective relays have well-established, selectable, and adjustable time and current (or other operating parameter) operating characteristics.
Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.
A relay Electromechanical relay principle Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off. A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple ...
A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three-phase motors also vibrate less and hence last longer than single-phase motors of the same power used under the same conditions. [32]
24 – Volts per Hertz Relay (in some old analog applications, a 59 and an 81 device would be chained together as a 59/81 to implement the equivalent of V/Hz protection) 25 – Synchronizing or Synchronism-check Device; 26 – Apparatus Thermal Device, Temperature Switch; 27 – Undervoltage Relay; 27P - Phase Undervoltage; 27S - DC ...
The non-tripped state is typically 24 VDC, and the tripped state (when the safety barrier has been violated) 0 VDC. If a wire were to break between the light curtain and the safety relay, the safety relay would trip to the safe state. The OSSD outputs are self-checked. In the non-tripped state, the outputs periodically pulse low.
Sometimes as a precaution against out-of-step connection of a machine to a system, a "synchro check" relay is installed that prevents closing the generator circuit breaker unless the machine is within a few electrical degrees of being in-phase with the system. Synchro check relays are also applied in places where several sources of supply may ...