PACs are deployed in SCADA systems to provide RTU and PLC functions. In many electrical substation SCADA applications, "distributed RTUs" use information processors or station computers to communicate with digital protective relays, PACs, and other devices for I/O, and communicate with the SCADA master in lieu of a traditional RTU.
Substation integration refers to combining data from the IED's local to a substation so that there is a single point of contact in the substation for all of the I&C data. Power-system automation processes rely on data acquisition; power-system supervision and power-system control all working together in a coordinated automatic fashion.
IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations.It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems. [1]
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server. [2]
The core packages of the CIM are defined in IEC 61970-301, with a focus on the needs of electricity transmission, where related applications include energy management system, SCADA, and planning and optimization. IEC 61970-501 and 61970-452 define an XML format for network model exchanges using RDF.
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
The gateway processor approach is similar to the networked server except it is intended for legacy systems with minimal communications networking capability and so has the lowest performance. In the most minimal situation the ICCP gateway may communicate with the SCADA host via a serial port in a similar manner to the SCADA RTUs.
Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control. The word substation comes from the days before the distribution system became a grid. As central generation stations became ...