Concrete degradation may have many different causes. Concrete is mostly damaged by the corrosion of reinforcement bars due to the carbonatation of hardened cement paste or chloride attack under wet conditions. Chemical damage is caused by the formation of expansive products produced by chemical reactions (from carbonatation, chlorides, sulfates ...
Worse still, the number of steel reinforcement bars embedded into the concrete was 8, not the required 16, which gave the building only half its needed strength. Steel reinforcements intended to strengthen the concrete floor were placed 10 cm from the top instead of 5 cm, decreasing the structure's strength by about another 20%.
(2) The thermal expansion coefficients of concrete and steel are so close (1.0 × 10 −5 to 1.5 × 10 −5 for concrete and 1.2 × 10 −5 for steel) that the thermal stress-induced damage to the bond between the two components can be prevented. (3) Concrete can protect the embedded steel from corrosion and high-temperature induced softening.
The EN 10080: Steel for the reinforcement of concrete is a European Standard. This standard is referenced by EN 1992 . This standard specifies general requirements and definitions for performance characteristics of steel reinforcement suitable for welding, which is used for reinforcement of concrete structures, supplied as finished products:
Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1] Reinforced concrete is the most common form of concrete. The reinforcement is often steel rebar (mesh, spiral, bars and other forms). Structural fibers of various materials are ...
The derivation of the maximum arching moment of resistance of laterally restrained concrete bridge deck slabs utilised Rankin's [21] idealised elastic-plastic stress-strain criterion for concrete, valid for concrete cylinder strengths up to at least 70N/mm 2, which he had derived on the basis of Hognestad, Hanson and McHenry's [23] ultimate ...
The initiation time is related to the rate at which carbonation propagates in the concrete cover thickness.Once that carbonation reaches the steel surface, altering the local pH value of the environment, the protective thin film of oxides on the steel surface becomes instable, and corrosion initiates involving an extended portion of the steel surface.
Rebar (short for reinforcing bar), known when massed as reinforcing steel or steel reinforcement, [1] is a tension device added to concrete to form reinforced concrete and reinforced masonry structures to strengthen and aid the concrete under tension. Concrete is strong under compression, but has low tensile strength.