enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Galvanometer - Wikipedia

    en.wikipedia.org/wiki/Galvanometer

    The galvanometer is oriented so that the plane of the coil is vertical and aligned along parallel to the horizontal component B H of the Earth's magnetic field (i.e. parallel to the local "magnetic meridian"). When an electric current flows through the galvanometer coil, a second magnetic field B is created. At the center of the coil, where the ...

  3. Microchannel plate detector - Wikipedia

    en.wikipedia.org/wiki/Microchannel_plate_detector

    A microchannel plate is a slab made from resistive material (most often glass) 0.5 to 2mm thick with a regular array of tiny tubes (microchannels) leading from one face to the other. The microchannels are typically 5-20 micrometers in diameter, parallel to each other and enter the plate at a small angle to the surface (8-13° from normal ...

  4. Glossary of electrical and electronics engineering - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_electrical_and...

    The mathematical relationship between voltage, current, and resistance. one-line diagram A simplified schematic diagram of a power system. on-premises wiring Telecommunications wiring owned by the customer. open-circuit test A test, of a transformer or other device, with no load connected. open-circuit voltage

  5. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]

  6. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    At two multiples of the rated current, the recloser's rapid trip curve can cause a trip (off circuit) in as little as 1.5 cycles (or 30 milliseconds). During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current.

  8. Eddy current - Wikipedia

    en.wikipedia.org/wiki/Eddy_current

    In electromagnetism, an eddy current (also called Foucault's current) is a loop of electric current induced within conductors by a changing magnetic field in the conductor according to Faraday's law of induction or by the relative motion of a conductor in a magnetic field. Eddy currents flow in closed loops within conductors, in planes ...

  9. High-voltage direct current - Wikipedia

    en.wikipedia.org/wiki/High-voltage_direct_current

    A block diagram of a bipolar HVDC transmission system, between two stations designated A and B. AC – represents an alternating current network CON – represents a converter valve, either rectifier or inverter, TR represents a power transformer, DCTL is the direct-current transmission line conductor, DCL is a direct-current filter inductor ...

  1. Related searches what will detect current in parallel plate system with one pole diagram

    microchannel plate detectorsgalvanometer pole design