Reflective foil, bubble foil insulations, and radiant barriers are noted for their ability to reflect unwanted solar radiation in hot climates, when applied properly. Reflective foils are fabricated from aluminum foils with a variety of backings such as roofing paper, craft paper, plastic film, polyethylene bubbles, or cardboard.
As it is an opaque material, the remaining 10 percent must be reflected. Conversely, a low-e material such as aluminum foil has a thermal emissivity/absorptance value of 0.03 and as an opaque material, the thermal reflectance value must be 1.0 - 0.03 =0.97, meaning it reflects 97 percent of radiant thermal energy. Low-emissivity building ...
Uses include the underside of roof sheathing, ceilings, and on walls. For best results, this should not be used as a cavity fill type insulation. Foil-backed bubble pack. This is thin, more flexible than rigid panels, works as a vapor barrier, and resembles plastic bubble wrap with aluminum foil on both sides.
Aluminum foil, 0.05 US perm (2.9 SI perm). Paper-backed aluminum. Asphalt or coal tar pitch, typically hot-applied to concrete roof decks along with reinforcement felts. Polyethylene plastic sheet, 4 or 6 thou (0.10 or 0.15 mm), 0.03 US perm (1.7 SI perm).
In modern usage of the term in Australia, sarking refers to a laminated aluminium foil layer, or reflective foil laminate (RFL), that is installed on the roof trusses, beneath the battens, supporting a tile or metal deck roof. It acts as additional radiative (radiant barrier) and convective insulation and provides a condensation barrier. [1]
The thermal grease 860 is a silicone oil with a Zinc Oxide filler and 8616 and 8617 are synthetic oils with various fillers including Aluminum Oxide and Boron Nitride. At 25 °C the densities are 2.40, 2.69 and 1.96 g/mL for the greases 860, 8616 and 8617 respectively.
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
If the renovation is of a smaller nature, the renovation directive applies. Examples of renovation are post-insulation of a cavity wall and post-insulation of a sloping roof against the roof boarding or under the tiles. Note that every renovation must meet the minimum Rc value of 1.3 W/(m 2 ⋅K). If the current insulation has a higher ...