Ad
related to: difference between thermistor and rtd
Search results
Results from the WOW.Com Content Network
If process temperatures are between −200 and 500 °C (−328.0 and 932.0 °F), an industrial RTD is the preferred option. Thermocouples have a range of −180 to 2,320 °C (−292.0 to 4,208.0 °F), [ 9 ] so for temperatures above 500 °C (932 °F) it is the contact temperature measurement device commonly found in physics laboratories.
NTC thermistors are widely used as inrush-current limiters and temperature sensors, while PTC thermistors are used as self-resetting overcurrent protectors and self-regulating heating elements. An operational temperature range of a thermistor is dependent on the probe type and is typically between −100 and 300 °C (−148 and 572 °F).
The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.
Thermistors; Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.
Furthermore the second paragraph of this very article says "Thermistors differ from resistance temperature detectors (RTD) in that the material used in a thermistor is generally a ceramic or polymer, while RTDs use pure metals." A lamp is much more like an RTD than a thermistor.Constant314 03:43, 2 February 2012 (UTC)
The equation model converts the resistance actually measured in a thermistor to its theoretical bulk temperature, with a closer approximation to actual temperature than simpler models, and valid over the entire working temperature range of the sensor.
Some sensors require external voltage or current source of excitation, These sensors are called active sensors. (E.g. a temperature sensor like a thermistor & RTD, a pressure sensor (piezo-resistive and capacitive), etc.). The stability and precision of the excitation signal directly relates to the sensor accuracy and stability.
The integrated circuit sensor may come in a variety of interfaces — analogue or digital; for digital, these could be Serial Peripheral Interface, SMBus/I 2 C or 1-Wire.. In OpenBSD, many of the I 2 C temperature sensors from the below list have been supported and are accessible through the generalised hardware sensors framework [3] since OpenBSD 3.9 (2006), [4] [5]: §6.1 which has also ...
Ad
related to: difference between thermistor and rtd