Search results

  1. Results from the WOW.Com Content Network
  2. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.

  3. Oxygen compatibility - Wikipedia

    en.wikipedia.org/wiki/Oxygen_compatibility

    In an oxygen system the presence of oxygen is implied, and in a sufficiently high partial pressure of oxygen, most materials can be considered fuel. Potential ignition sources are present in almost all oxygen systems, but fire hazards can be mitigated by controlling the risk factors associated with the oxygen, fuel, or heat, which can limit the ...

  4. Diving regulator - Wikipedia

    en.wikipedia.org/wiki/Diving_regulator

    A diving regulator or underwater diving regulator is a pressure regulator that controls the pressure of breathing gas for underwater diving.The most commonly recognised application is to reduce pressurized breathing gas to ambient pressure and deliver it to the diver, but there are also other types of gas pressure regulator used for diving applications.

  5. Mechanism of diving regulators - Wikipedia

    en.wikipedia.org/wiki/Mechanism_of_diving_regulators

    The mechanism of diving regulators is the arrangement of components and function of gas pressure regulators used in the systems which supply breathing gases for underwater diving. Both free-flow and demand regulators use mechanical feedback of the downstream pressure to control the opening of a valve which controls gas flow from the upstream ...

  6. Anaesthetic machine - Wikipedia

    en.wikipedia.org/wiki/Anaesthetic_machine

    In essence, the nitrous-oxide regulator is a 'slave' of the oxygen regulator. i.e., if oxygen pressure is lost then the other gases can not flow past their regulator. hypoxic-mixture alarms (hypoxy guards or ratio controllers) to prevent gas mixtures which contain less than 21–25% oxygen being delivered to the patient. In modern machines it ...

  7. Self-contained breathing apparatus - Wikipedia

    en.wikipedia.org/wiki/Self-contained_breathing...

    An open circuit SCBA typically has three main components: a high-pressure gas storage cylinder, (e.g., 2,216 to 5,500 psi (15,280 to 37,920 kPa), about 150 to 374 atmospheres), a pressure regulator, and a respiratory interface, which may be a mouthpiece, half mask or full-face mask, assembled and mounted on a framed carrying harness. [2]

  8. High altitude breathing apparatus - Wikipedia

    en.wikipedia.org/wiki/High_altitude_breathing...

    Some field user maintenance is possible using the spare parts kit. The schematic diagram indicates a partial rebreather mask type. [28] The Poisk regulator is a constant flow device which can be adjusted between 1 and 4 litres per minute in 0.25 litre per minute increments. [clarification needed] It has a mass of 0.35 kg. [7]

  9. Flashback arrestor - Wikipedia

    en.wikipedia.org/wiki/Flashback_arrestor

    The flashback arrestors are suitable for most technical gases (fuel gases) such as acetylene, hydrogen, methane, propane, propylene and butane as well as oxygen and compressed air. Flashback arrestors have to be tested for gas non-return, for tightness and for gas flow by a qualified person depending on the country specific regulations.