Search results
Results from the WOW.Com Content Network
For this reason, the blood flow velocity is the fastest in the middle of the vessel and slowest at the vessel wall. In most cases, the mean velocity is used. [18] There are many ways to measure blood flow velocity, like videocapillary microscoping with frame-to-frame analysis, or laser Doppler anemometry. [19]
For example, oxytocin has a half-life of typically about three minutes in the blood when given intravenously. Peripherally administered (e.g. intravenous) peptides like oxytocin cross the blood-brain-barrier very poorly, although very small amounts (< 1%) do appear to enter the central nervous system in humans when given via this route. [31]
Pulsus bisferiens, also known as biphasic pulse, is an aortic waveform with two peaks per cardiac cycle, a small one followed by a strong and broad one. [1] It is a sign of problems with the aorta , including aortic stenosis and aortic regurgitation , as well as hypertrophic cardiomyopathy causing subaortic stenosis.
Vascular resistance occurs when the vessels away from the heart oppose the flow of blood. Resistance is an accumulation of three different factors: blood viscosity, blood vessel length and vessel radius. [30] Blood viscosity is the thickness of the blood and its resistance to flow as a result of the different components of the blood.
The classic definition by MP Spencer and AB Denison of compliance is the change in arterial blood volume due to a given change in arterial blood pressure ().They wrote this in the "Handbook of Physiology" in 1963 in work entitled "Pulsatile Flow in the Vascular System".
Below are several examples of differing types of local blood flow regulation by specific organ type or organ system. In each case, there is a specific type of intrinsic regulation occurring in order to maintain or alter blood flow to that given organ alone, instead of creating a systemic change that would affect the entire body.
Vascular resistance is the resistance that must be overcome for blood to flow through the circulatory system.The resistance offered by the systemic circulation is known as the systemic vascular resistance or may sometimes be called by another term total peripheral resistance, while the resistance caused by the pulmonary circulation is known as the pulmonary vascular resistance.
The jugular venous pulsation has a biphasic waveform. The a wave corresponds to right atrial contraction and ends synchronously with the carotid artery pulse. The peak of the 'a' wave demarcates the end of atrial systole. The x descent follows the 'a' wave and corresponds to atrial relaxation and rapid atrial filling due to low pressure.