Search results
Results from the WOW.Com Content Network
An internal wastegate is a built-in bypass valve and passage within the turbocharger housing which allows excess exhaust pressure to bypass the turbine into the downstream exhaust. Control of the internal wastegate valve by a pressure signal from the intake manifold is identical to that of an external wastegate.
It is a no-load condition in a gas turbine, turbocharger or industrial axial compressor but overload in an industrial centrifugal compressor. [29] Hiereth et al. [30] shows a turbocharger compressor full-load, or maximum fuelling, curve runs up close to the surge line. A gas turbine compressor full-load line also runs close to the surge line.
The facility is authorized to install up to 225 wind turbines totaling 450 MW and averaging 150 MW distributed over 25,000 acres (10,000 ha). Each turbine's supporting tower must be 265–280 feet (81–85 m) tall; combined with wind turbine blades, each unit may be 400–445 feet (122–136 m) in height.
The LMS100 comprises a low-pressure compressor, an intercooler, a supercore and a power turbine. The supercore (comprising a HP compressor, compressor rear frame, high-pressure turbine and intermediate pressure turbine) is a further development of the LM6000, which in turn was based on the CF6-80C2. The low-pressure compressor is from the 6FA ...
Because a turbine expands from high to low pressure, there is no such thing as turbine surge or stall. The turbine needs fewer stages than the compressor, mainly because the higher inlet temperature reduces the deltaT/T (and thereby the pressure ratio) of the expansion process. The blades have more curvature and the gas stream velocities are ...
Schipkau GICON Wind Turbine, whose construction started on September 19, 2024, will be the tallest wind turbine in the world and the second tallest structure in Germany when completed. It will consist of a 300-meter-high lattice tower, on which a Vensys 126 wind turbine with a nominal power of 3.8 MW and a rotor diameter of 126 meters will be ...
be changed to: "The primary function of the wastegate is to balance the forces on the shaft connecting the compressor to the turbine. This helps stabilize boost pressure in turbocharger systems, to protect the engine and the turbocharger." Reason: The current statement explains the result of the wastegate and not the task it performs.
An energy tower (also known as a downdraft energy tower, because the air flows down the tower) is a tall (1,000 meters) and wide (400 meters) hollow cylinder with a water spray system at the top. Pumps lift the water to the top of the tower and then spray the water inside the tower. Evaporation of water cools the hot, dry air hovering at the top.