Search results
Results from the WOW.Com Content Network
Coarse bubble diffusers produce 1/4 to 1/2 inch (6.4 to 13 mm) bubbles which rise rapidly from the floor of a wastewater treatment plant or sewage treatment plant tank. They are typically used in grit chambers, equalization basins, chlorine contact tanks, and aerobic digesters, and sometimes also in aeration tanks. Generally they are better at ...
A schematic cross-section of the contact face of the bed media in a rotating biological contactor (RBC) [7] The rotating packs of disks (known as the media) are contained in a tank or trough and rotate at between 2 and 5 revolutions per minute. Commonly used plastics for the media are polyethylene, PVC and expanded polystyrene. The shaft is ...
CT Values are an important part of calculating disinfectant dosage for the chlorination of drinking water.A CT value is the product of the concentration of a disinfectant (e.g. free chlorine) and the contact time with the water being disinfected.
Chlorine is a strong oxidant that rapidly kills many harmful micro-organisms. Because chlorine is a toxic gas, there is a danger of a release associated with its use. This problem is avoided by the use of sodium hypochlorite, which is a relatively inexpensive solution used in household bleach that releases free chlorine when dissolved in water ...
An atmospheric tank is a container for holding a liquid at atmospheric pressure. The major design codes for welded atmospheric tanks are API 650 and API 620. API 653 is used for analysis of in-service storage tanks. In Europe the applicable design code is EN 14015, which uses load cases from Eurocode 3 (EN 1993), part 4-2.
Key to the production of chlorine is the operation of the brine saturation/treatment system. Maintaining a properly saturated solution with the correct purity is vital, especially for membrane cells. Many plants have a salt pile which is sprayed with recycled brine. Others have slurry tanks that are fed raw salt and recycled brine.
The solution travels to a tank that separates the hydrogen gas based on its low density. [1] Only water and sodium chloride are used. The simplified chemical reaction is: NaCl + H 2 O + energy → NaOCl + H 2 [citation needed] That is, energy is added to sodium chloride (table salt) in water, producing sodium hypochlorite and hydrogen gas.
Stabilized forms of chlorine persist after the effluent is dispersed, and can kill plants in the leach field. Since the ATS contains a living ecosystem of microbes to digest the waste products in the water, excessive amounts of items such as bleach or antibiotics can damage the ATS environment and reduce treatment effectiveness.