  2. Nyquist frequency - Wikipedia

    en.wikipedia.org/wiki/Nyquist_frequency

    For a given sampling rate (samples per second), the Nyquist frequency (cycles per second) is the frequency whose cycle-length (or period) is twice the interval between samples, thus 0.5 cycle/sample. For example, audio CDs have a sampling rate of 44100 samples/second. At 0.5 cycle/sample, the corresponding Nyquist frequency is 22050 cycles/second .

  3. Nyquist rate - Wikipedia

    en.wikipedia.org/wiki/Nyquist_rate

    Fig 1: Typical example of Nyquist frequency and rate. They are rarely equal, because that would require over-sampling by a factor of 2 (i.e. 4 times the bandwidth). In signal processing , the Nyquist rate , named after Harry Nyquist , is a value equal to twice the highest frequency ( bandwidth ) of a given function or signal.

  4. Sampling (signal processing) - Wikipedia

    en.wikipedia.org/wiki/Sampling_(signal_processing)

    When a bandpass signal is sampled slower than its Nyquist rate, the samples are indistinguishable from samples of a low-frequency alias of the high-frequency signal. That is often done purposefully in such a way that the lowest-frequency alias satisfies the Nyquist criterion, because the bandpass signal is still uniquely represented and ...

  5. Nyquist–Shannon sampling theorem - Wikipedia

    en.wikipedia.org/wiki/Nyquist–Shannon_sampling...

    The sample rate must exceed the Nyquist rate for the samples to suffice to represent (). The threshold / is called the Nyquist frequency and is an attribute of the sampling equipment. All meaningful frequency components of the properly sampled () exist below the Nyquist frequency.

  6. Oversampling - Wikipedia

    en.wikipedia.org/wiki/Oversampling

    The sampling theorem states that sampling frequency would have to be greater than 200 Hz. Sampling at four times that rate requires a sampling frequency of 800 Hz. This gives the anti-aliasing filter a transition band of 300 Hz ((f s /2) − B = (800 Hz/2) − 100 Hz = 300 Hz) instead of 0 Hz if the sampling frequency was 200 Hz. Achieving an ...

  7. Downsampling (signal processing) - Wikipedia

    en.wikipedia.org/wiki/Downsampling_(signal...

    Decimators can be used to reduce the sampling frequency, whereas interpolators can be used to increase it. Milic, Ljiljana (2009). Multirate Filtering for Digital Signal Processing. New York: Hershey. p. 35. ISBN 978-1-60566-178-0. Sampling rate conversion systems are used to change the sampling rate of a signal.

  8. Undersampling - Wikipedia

    en.wikipedia.org/wiki/Undersampling

    A lower value of n will also lead to a useful sampling rate. For example, using n = 4, the FM band spectrum fits easily between 1.5 and 2.0 times the sampling rate, for a sampling rate near 56 MHz (multiples of the Nyquist frequency being 28, 56, 84, 112, etc.). See the illustrations at the right.

  9. Frequency ambiguity resolution - Wikipedia

    en.wikipedia.org/wiki/Frequency_ambiguity_resolution

    The Nyquist frequency will also change when the PRF is changed. This is explained best using an example with 2 different PRF, although real systems use a different method. In the example, PRF A can detect true speed up to 600MPH and PRF B can detect true speed up to 500MPH.