enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. 1951 USAF resolution test chart - Wikipedia

    en.wikipedia.org/.../1951_USAF_resolution_test_chart

    A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens.

  3. Angular resolution - Wikipedia

    en.wikipedia.org/wiki/Angular_resolution

    In a dry objective or condenser, this gives a maximum NA of 0.95. In a high-resolution oil immersion lens, the maximum NA is typically 1.45, when using immersion oil with a refractive index of 1.52. Due to these limitations, the resolution limit of a light microscope using visible light is about 200 nm.

  4. Optical resolution - Wikipedia

    en.wikipedia.org/wiki/Optical_resolution

    The ability of a lens to resolve detail is usually determined by the quality of the lens, but is ultimately limited by diffraction.Light coming from a point source in the object diffracts through the lens aperture such that it forms a diffraction pattern in the image, which has a central spot and surrounding bright rings, separated by dark nulls; this pattern is known as an Airy pattern, and ...

  5. Oil immersion - Wikipedia

    en.wikipedia.org/wiki/Oil_immersion

    In light microscopy, oil immersion is a technique used to increase the resolving power of a microscope. This is achieved by immersing both the objective lens and the specimen in a transparent oil of high refractive index , thereby increasing the numerical aperture of the objective lens.

  6. Numerical aperture - Wikipedia

    en.wikipedia.org/wiki/Numerical_aperture

    In microscopy, NA is important because it indicates the resolving power of a lens. The size of the finest detail that can be resolved (the resolution) is proportional to ⁠ λ / 2NA ⁠, where λ is the wavelength of the light. A lens with a larger numerical aperture will be able to visualize finer details than a lens with a smaller numerical ...

  7. Dawes' limit - Wikipedia

    en.wikipedia.org/wiki/Dawes'_limit

    Dawes' limit is a formula to express the maximum resolving power of a microscope or telescope. [1] It is so named after its discoverer, William Rutter Dawes, [2] although it is also credited to Lord Rayleigh. The formula takes different forms depending on the units.

  8. Optical sectioning - Wikipedia

    en.wikipedia.org/wiki/Optical_sectioning

    With no modification to the microscope, i.e. with a simple wide field light microscope, the quality of optical sectioning is governed by the same physics as the depth of field effect in photography. For a high numerical aperture lens, equivalent to a wide aperture, the depth of field is small (shallow focus) and gives good optical sectioning.

  9. Resolving power - Wikipedia

    en.wikipedia.org/wiki/Resolving_power

    Resolving power is the capacity of an instrument to resolve two points which are close together. Specifically, resolving power may refer to: Angular resolution