enow.com Web Search

  1. Ad

    related to: how to calculate balancing valve temperature control
    • Installations

      Used In a Wide Range of Buildings

      High-Rise, Health Care, Commercial

    • Contact Us

      Call Or Message Us To Discuss

      Your Project’s Requirements

    • Find Your Rep

      Find Your Local Rep

      To Learn More about CircuitSolver

    • About Us

      1st Thermostatic Valve for DHW

      Exclusive Actuator Technology

Search results

  1. Results from the WOW.Com Content Network
  2. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Traditional control valves make it inevitable. As we size a control valve, the K v calculated almost certainly will not match the K v of the nearest appropriate valve. For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more ...

  3. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  4. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    Balancing is the methodical regulation of system fluid flows (air or water) through the use of acceptable procedures to achieve the desired or specified design airflow or water flow. When beginning the balance of a system, you must locate the terminal with the least amount of flow in regards to the engineer's drawing.

  5. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  6. Choked flow - Wikipedia

    en.wikipedia.org/wiki/Choked_flow

    The above equations calculate the steady state mass flow rate for the pressure and temperature existing in the upstream pressure source. If the gas is being released from a closed high-pressure vessel, the above steady state equations may be used to approximate the initial mass flow rate. Subsequently, the mass flow rate decreases during the ...

  7. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    Allows water to be stored at a higher temperature; Group Control. These provide a uniform distribution temperature for all hot water outlets in a household. Designed for multi-point applications; High flow rates (from 14 to 51 US gallons per minute (53 to 193 L/min) at 45 pounds per square inch (3.1 bar)) Temperature stability; Point-of-Use

  8. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.

  9. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    Tuning a control loop is the adjustment of its control parameters (proportional band/gain, integral gain/reset, derivative gain/rate) to the optimum values for the desired control response. Stability (no unbounded oscillation) is a basic requirement, but beyond that, different systems have different behavior, different applications have ...

  1. Ad

    related to: how to calculate balancing valve temperature control