enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Anterior chamber of eyeball - Wikipedia

    en.wikipedia.org/wiki/Anterior_chamber_of_eyeball

    The EZ ratio method is one way to calculate the estimated anterior chamber depth. [2] To start, the patient looks at a target in the distance with one eye covered. The examiner takes a digital photograph of the open, examined eye, from the side, perpendicular to the visual axis (a profile photograph).

  3. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    The aim of an accurate intraocular lens power calculation is to provide an intraocular lens (IOL) that fits the specific needs and desires of the individual patient. The development of better instrumentation for measuring the eye's axial length (AL) and the use of more precise mathematical formulas to perform the appropriate calculations have significantly improved the accuracy with which the ...

  4. Van Herick technique - Wikipedia

    en.wikipedia.org/wiki/Van_Herick_technique

    The anterior chamber drainage angle is then graded as a ratio between the peripheral anterior chamber depth and corneal thickness (AC : C ratio) [5] or expressed traditionally as a fraction [6] to provide the Van Herick's result. Grading can also be obtained by distinguishing the structures visible upon observation.

  5. Tissue-to-air ratio - Wikipedia

    en.wikipedia.org/wiki/Tissue-to-air_ratio

    Tissue-air ratio is defined as the ratio of the dose to water at a given depth to the dose in air measured with a buildup cap: = (,) (,) where D(f,z) is the dose at a given depth z and distance focus-detector f; and D(f,0) is the dose in air (z=0).

  6. Anterior chamber angle - Wikipedia

    en.wikipedia.org/wiki/Anterior_chamber_angle

    The anterior chamber angle is a part of the eye located between the cornea and iris which contains the trabecular meshwork. The size of this angle is an important determinant of the rate aqueous humour flows out of the eye, and thus, the intraocular pressure. The anterior chamber angle is the structure which determines the anterior chamber depth.

  7. Phakic intraocular lens - Wikipedia

    en.wikipedia.org/wiki/Phakic_intraocular_lens

    Anterior chamber depth (ACD, i.e. the distance between the crystalline lens and cornea including the corneal thickness) is required before the surgery and measured with the use of ultrasound. Iris-fixated IOLs are fixated to iris therefore they have the advantage of being one size (8.5 mm).

  8. Intraocular lens - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens

    An anterior chamber IOL (ACIOL) Posterior chamber IOL (PCIOL). This is by far the most common type of implanted lens after cataract surgery, as this is the natural and optimum position for a lens. [citation needed] Anterior chamber IOL (ACIOL). A less-common type of intraocular lens, which is sometimes used if a PCIOL is not an option for a ...

  9. Cataract surgery - Wikipedia

    en.wikipedia.org/wiki/Cataract_surgery

    The depth of the anterior chamber and position of the posterior capsule may be maintained during surgery by OVDs or an anterior chamber maintainer, which is an auxiliary cannula providing a sufficient flow of buffered saline solution (BSS) to maintain stability of the shape of the chamber and internal pressure.