K-Series Joists are standardized regarding depths, spans, and load-carrying capacities. There are 63 separate designations in the Load Tables, representing joist depths from 10 inches (250 mm) through 30 inches (760 mm) in 2 inches (51 mm) increments and spans through 60 feet (18,000 mm).
There are approved formulas for calculating the depth required and reducing the depth as needed; however, a rule of thumb for calculating the depth of a wooden floor joist for a residential property is to take half the span in feet, add two, and use the resulting number as the depth in inches; for example, the joist depth required for a 14-foot ...
In the framing of a deck or floor system, a rim joist is attached perpendicular to the joists, and provides lateral support for the ends of the joists while capping off the end of the floor or deck system. Rim joists are not to be confused with end joists, which are the first and last joists at the ends of a row of joists that make up a floor ...
I-joists, I-beams engineered from wood with fiberboard or laminated veneer lumber, or both, are also becoming increasingly popular in construction, especially residential, as they are both lighter and less prone to warping than solid wooden joists. However, there has been some concern as to their rapid loss of strength in a fire if unprotected.
Invented in 1969, the I-joist is an engineered wood product that has great strength in relation to its size and weight. The biggest notable difference from dimensional lumber is that the I-joist carries heavy loads with less lumber than a dimensional solid wood joist. [1] As of 2005, approximately 50% of all wood light framed floors used I-joists.
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...
The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.
The Precast/Prestressed Concrete Institute (PCI) published the double tee load capacity calculation (load tables) for the first time in the PCI Design Handbook in 1971. The load tables use the code to identify double tee span type by using the width in feet, followed by "DT", followed by depth in inches, for example, 4DT14 is for 4-foot (1.2 m ...