The system can be stand alone (i.e. using dedicated loudspeakers, which can also feature integrated strobe lights), or the system can accommodate public address system functionality. In 1973, the Autocall fire alarm company (merged to SimplexGrinnell then relaunched), manufactured the first voice evacuation system. [6]
A Wheelock AS horn/strobe. In 1995, Wheelock introduced the AS, a combination horn and strobe. The AS was first created with a vertical position strobe on the right side of the horn, except for 110 candela models, which used a horizontal strobe. In 1997 when the NS was introduced, the strobe on all AS models was moved to the horizontal position.
Some fire alarm systems utilize emergency voice alarm communication systems (EVAC) [17] to provide prerecorded and manual voice messages. Voice alarm systems are typically used in high-rise buildings, arenas, and other large "defend-in-place" occupancies such as hospitals and detention facilities where total evacuation is difficult to achieve.
A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and ...
The SpectrAlert series included horn strobes, strobes, remote horns, chimes, chime strobes, speakers, and speaker strobes. A main feature of these alarms was the ability to sync them using a System Sensor MDL sync module or the System Sensor sync protocol on a supported fire alarm control panel. Three years after the initial release of the ...
Manual fire alarm activation requires human intervention, as distinct from automatic fire alarm activation such as that provided through the use of heat detectors and smoke detectors. It is, however, possible for call points/pull stations to be used in conjunction with automatic detection as part of the overall fire detection and alarm system .
Photoelectric detectors and ionization detectors differ in their performance depending on the type of smoke generated by a fire. A presentation by Siemens and the Canadian Fire Alarm Association reports that the ionization detector is the best at detecting incipient-stage fires with invisibly small particles, fast-flaming fires with smaller 0. ...
The fire detection and fire alarm system subcommittee of ISO/TC 21, Equipment for Fire Protection and Fire Fighting, had oversight for development of five standards covering detectors, control and indicating equipment. ISO 7240-2:3003 specifies requirements, test methods and performance criteria for control and indicating equipment (c.i.e.) for ...