enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Optical path length - Wikipedia

    en.wikipedia.org/wiki/Optical_path_length

    The optical path difference between the paths taken by two identical waves can then be used to find the phase change. Finally, using the phase change, the interference between the two waves can be calculated. Fermat's principle states that the path light takes between two points is the path that has the minimum optical path length.

  3. Fizeau experiment - Wikipedia

    en.wikipedia.org/wiki/Fizeau_experiment

    His common-path interferometer design provided automatic compensation of path length, so that white light fringes were visible at once as soon as the optical elements were aligned. Topologically, the light path was that of a Sagnac interferometer with an even number of reflections in each light path.

  4. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.

  5. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    The cuvette is filled with sample, light is passed through the sample and intensity readings are taken. The slope spectroscopy technique can be applied using the same methods as in absorption spectroscopy. With the advent of accurate linear stages, variable pathlength absorption spectroscopy is easily applied experimentally.

  6. Fourier-transform infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_infrared...

    Light is reflected from the two mirrors back to the beam splitter and some fraction of the original light passes into the sample compartment. There, the light is focused on the sample. On leaving the sample compartment the light is refocused on to the detector. The difference in optical path length between the two arms to the interferometer is ...

  7. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Spectrophotometry is a tool that hinges on the quantitative analysis of molecules depending on how much light is absorbed by colored compounds. Important features of spectrophotometers are spectral bandwidth (the range of colors it can transmit through the test sample), the percentage of sample transmission, the logarithmic range of sample ...

  8. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    The light path of a bright-field microscope is extremely simple; no additional components are required beyond the normal light-microscope setup. The light path begins at the illuminator or the light source on the base of the microscope. Often a halogen lamp is used. The light travels through the objective lens into the ocular lens, through ...

  9. Cuvette - Wikipedia

    en.wikipedia.org/wiki/Cuvette

    The smallest cuvettes can hold 70 microliters, while the largest can hold 2.5 milliliters or more. The width determines the length of the light path through the sample, which affects the calculation of the absorbance value. Many cuvettes have a light path of 10 mm (0.39 in), which simplifies calculation of the coefficient of absorption.