In electric power distribution, a service drop is an overhead electrical line running from a utility pole, to a customer's building or other premises. It is the point where electric utilities provide power to their customers. [1] The customer connection to an underground distribution system is usually called a "service lateral".
Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...
A pole-mounted three-phase distribution transformer. Low-voltage feeders distributing power to households are placed below the transformer. A low-voltage network or secondary network is a part of electric power distribution which carries electric energy from distribution transformers to electricity meters of end customers.
An overhead power line is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (commonly multiples of three) suspended by towers or poles.
For electric power supply, a cable is run either overhead or underground into a distribution board in the home. A distribution board, or circuit breaker panel, is typically a metal box mounted on a wall of the home. In many new homes, the location of the electrical switchboard is on the outside of the external wall of the garage.
However, due to Kirchhoff's Laws, the voltage magnitude and thus the service voltage to customers will in fact vary along the length of a conductor such as a distribution feeder (see Electric power distribution). Depending on law and local practice, actual service voltage within a tolerance band such as ±5% or ±10% may be considered acceptable.
The clearance values may depend on the heights and types of the obstacles. For example, in Flanders, the horizontal clearance next to the paths for poles, lampposts and trees is 0.75 metres (2 ft 6 in), and for walls and fences is 1 metre (3 ft 3 in). The horizontal clearance from the edge of the path to the curb is based on curb heights. For ...
The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association . [ 1 ]